News

Ursula Keller wins “Swiss Nobel” Marcel Benoist Prize- for pioneering work in ultrafast lasers
MUST2022 Conference- a great success!
New scientific highlights- by MUST PIs Wörner, Chergui, and Richardson
FELs of Europe prize for Jeremy Rouxel- “Development or innovative use of advanced instrumentation in the field of FELs”
Ruth Signorell wins Doron prizefor pioneering contributions to the field of fundamental aerosol science
New FAST-Fellow Uwe Thumm at ETH- lectures on Topics in Femto- and Attosecond Science
International Day of Women and Girls in Science- SSPh asked female scientists about their experiences
New scientific highlight- by MUST PIs Milne, Standfuss and Schertler
EU XFEL Young Scientist Award for Camila Bacellar,beamline scientist and group leader of the Alvra endstation at SwissFEL
Prizes for Giulia Mancini and Rebeca Gomez CastilloICO/IUPAP Young Scientist Prize in Optics & Ernst Haber 2021
Nobel Prize in Chemistry awarded to RESOLV Member Benjamin List- for the development of asymmetric organocatalysis
NCCR MUST at Scientifica 2021- Lightning, organic solar cells, and virtual molecules

IR-pump-IR-probe, UV/VIS-pump-IR-probe and 2D-IR spectroscopy

back
 
Location   Contact
Department of Chemistry
University of Zurich
Winterthurerstr. 190
8057 Zurich
 
  Peter Hamm
Tel +41 44 6354431
*pea8ten&r.x4han+mmy-@co6hef0m.d/uzv1h.u+chu
     

Setup / Configuration

 
 

Literature

 
Universal IR-pump-IR-probe, UV/VIS-pump-IR-probe and 2D-IR spectrometer, covering the spectral range from 1000-3500 cm-1 in the IR and 260-800 nm in the UV/VIS.   
  1. P. Hamm, R.A. Kaindl, J. Stenger, Noise suppression in femtosecond mid-infrared light sources, Opt. Lett. 25 (2000) 1798-1800
  2. J. Helbing and P. Hamm, A compact implementation of Fourier transform 2D-IR spectroscopy without phase ambiguity J. Opt. Soc. Am. B 28, (2011) 171–178
 
Hamm1. .Hamm2    The left/top image shows the complete measurement setup, which can be used as IR-pump-IR-probe, UV/VIS-pump-IR-probe or 2D-IR spectrometer in a routine and versatile manner due to a very modular design. An OPA is used as IR light source, delivering tunable 1-2 µJ, 100 fs pulses in the 1000-3500 cm-1 spectral range [1]. A 2nd and 3rd harmonic generator together with a NOPA is used to cover the UV/VIS range for pumping. The right image shows the compact Mach-Zehnder Interferometer needed for 2D IR spectroscopy in pump-probe geometry [2]. 
NCCR MUST Office : ETHZ IQE/ULP-HPT H3 | Auguste-Piccard-Hof 1 | 8093 Zurich | E-Mail
The National Centres of Competence in Research (NCCR) are a research instrument of the Swiss National Science Foundation